Full Line Product Catalog
Introduction – Wire-Mesh Grips
Table 2 Pulling-Grip Selection Table for Cables of Different Diameters to Be Pulled in One Grip
Table 3 Reference Table: Dimension Conversions for Ordering Tables
Grip Circumference Range
Grip Diameter Range
Metric Dimensions (mm)
Cat. No. Size Code
Decimal Inches Fractional Inches
Fractional Inches
Decimal Inches
Fractional Inches
Decimal Inches
0.12–0.24 0.25–0.36 0.37–0.49 0.50–0.61 0.62–0.74 0.75–0.99 1.00–1.24 1.25–1.49 1.50–1.99 2.00–2.49 2.50–2.99 3.00–3.49 3.50–3.99
1/8–15/64 1/4–23/64 3/8–31/64 1/2–39/64 5/8–47/64 3/4–63/64 1–1-15/64
3.17–5.95 6.35–9.13 9.52–12.30 12.70–15.48 15.88–18.65 19.05–25.00 25.40–31.35 31.75–37.70 38.10–50.40 50.80–63.10 63.50–75.80 76.20–88.50 88.90–101.20
25/32–1-11/64 1-11/64–1-37/64 1-37/64–1-15/16 1-37/64–2-3/8 2-3/8–3-5/32 3-5/32–3-15/16 3-15/16–4-23/32 4-23/32–5-33/64 5-33/64–6-19/64 6-19/64–7-55/64 7-55/64–9-7/16 9-7/16–11-1/64 11-1/64–12-37/64
.78–1.17 1.17–1.57 1.57–1.94 1.57–2.37 2.37–3.15 3.15–3.94 3.94–4.72 4.72–5.51 5.51–6.29 6.29–7.86 7.86–9.43 9.43–11.01 11.01–12.58
025 037 062 050 075 100 125 150 175 200 250 300 350
1/8–3/8 3/8–1/2 1/2–5/8 5/8–3/4
.12–.37 .37–.50 .50–.62 .62–.75 .75–1.00 1.00–1.25 1.25–1.50 1.50–1.75 1.75–2.00 2.00–2.50 2.50–3.00 3.00–3.50 3.50–4.00
3/4–1
1–1-1/4
1-1/4–1-1/2 1-1/2–1-3/4
1-1/4–1-31/64 1-1/2–1-63/64
1-3/4–2 2–2-1/2 2-1/2–3 3–3-1/2 3-1/2–4
2–2-31/64
2-1/2–2-63/64
3–3-31/64
3-1/2–3-63/64
“Grip Circumference Range” refers to circumference of all cables held together.
Table 5 Reference Table: AWG or MCM Wire Sizes This table is to be used as a guide only. Sizes may vary by manufacturer.
Wire Pulling Grips
1. Determine grip circumference range by measuring circumference of bundle of cables to be held. 2. Read down to locate correct range. 3. Read across for catalog number size code.
AWG OR MCM
Diameter
TTHN
THW
Example: For four cables together with circumference of 6.35", use grip containing catalog number size code “200”.
14 12 10
.105 .122 .153 .201 .257 .328 .356 .388 .450 .491 .537 .588 .646 .716 .771 .822 .869 .955
.162 .179 .199 .259 .323 .372 .401 .433 .508 .549 .595 .647 .705 .788 .843 .895 .942 1.03 1.12 1.19 1.22 1.38
8 6 4 3 2 1
Table 4 Reference Table: AWG Wire Sizes For your convenience, the following are representative portable cord diameters.
1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750
Conductors
AWG Wire Size & Type
2 5 ➊ ➋ ➊ ➋ ➊ ➋ ➊ ➋ 3 4
18 SO, STO 18 SJO, SJTO 16 SO, STO 16 SJO, SJTO 14 SO, STO 12 SO, STO 10 SO, STO
3.90 .310 .410 .330 .530 .610 .650 .810 .930
.390 .300 .405 .330 .530 .605 .640 .810 .930
.410 .330 .430 .340 .560 .640 .690 .910
.405 .330 .430 .360 .560 .640 .695 .910
.440 .360 .490 .390 .610 .680 .750 .990
.435 .360 .485 .390 .605 .670 .820 .990
.500
.495
–
–
.530
.525
–
–
.680 .750 .815
.685 .730
– – – –
–
8 SO, STO 6 SO, STO
1.080 1.080
242
1000
1.010 1.010 1.100 1.100 1.200 1.200
C.L. Blankenship, Inc. • 800-247-7747 • sales@clblankenship.com • www.clblankenship.com